InAir ADSS Standard Aramid

Applied for aerial installation on distribution and high voltage power lines, as well as railway catenary.

Applied inside buildings, in ducts, trays, blocks, tunnels, and collecting channels, on bridges, with a small risk of rodents’ attacks or in protecting tubes.

Also applied for direct-buried installation in protecting tubes.

+

InAir ADSS Standard Aramid

(Multi-Tube Aramid Double Jacket Cable)

  • 7
    Jacket
  • 6
    Reinforcing member – aramid yarns
  • 8
    Ripcord
  • 5
    Inner jacket
  • 4
    Water-blocking yarns
  • 3
    PBT loose tube filled with water-swellable gel
  • 2
    Optical fiber
  • 1
    Central strength member (dielectric fiberglass reinforced plastic)

Advantages

All dielectric construction – fully resistant to electromagnetic fields.

Wide range of operating temperatures. Installation temperature down to -30° C.

The most reliable among InAir cables. Double tensile strength.

Aerial installation on 35 kV power lines and above.

For construction of communication lines between towns and cities with distances between towers reaching 500 m.

Maximum tensile load up to 100 kN.

Features

Optical Fiber Specifications
Optical Fiber Color Identification


Crush for all cables of the group — from 171 lb/in
Tensile strength — 899 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.4800.5040.5310.555
Cable weight, lb/ft0.0760.0840.0910.098
Min bending radius, in7.2057.5597.9728.327



Tensile strength — 1349 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.4800.5040.5310.555
Cable weight, lb/ft0.0760.0840.0910.098
Min bending radius, in7.2057.5597.9728.327



Tensile strength — 1574


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.4840.5080.5310.555
Cable weight, lb/ft0.0780.0850.0910.098
Min bending radius, in7.2647.6187.9728.327



Tensile strength — 1798


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.4880.5080.5350.559
Cable weight, lb/ft0.0790.0850.0920.100
Min bending radius, in7.3237.6188.0318.386



Tensile strength — 2248


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.4920.5120.5390.563
Cable weight, in0.0810.0870.0950.102
Min bending radius, in7.3827.6778.0918.445



Tensile strength — 2698 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5000.5240.5470.571
Cable weight, lb/ft0.0840.0910.0980.106
Min bending radius, in7.5007.8548.2098.563



Tensile strength — 3372 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5120.5350.5550.579
Cable weight, lb/ft0.0900.0970.1010.110
Min bending radius, in7.6778.0318.3278.681



Tensile strength — 4496 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5430.5670.5980.622
Cable weight, lb/ft0.1000.1070.1100.118
Min bending radius, ib8.1508.5048.9769.331



Tensile strength — 5620


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5670.5870.6180.642
Cable weight, lb/ft0.1100.1150.1170.124
Min bending radius, in8.5048.7999.2729.626



Tensile strength — 6744 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5910.6100.6300.654
Cable weight, lb/ft0.1150.1220.1230.131
Min bending radius, in8.8589.1549.4499.803



Tensile strength — 7868 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.6340.6540.6770.701
Cable weight, lb/ft0.1290.1360.1430.150
Min bending radius, in9.5089.80310.15710.512



Tensile strength — 8992 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.6500.6690.6890.713
Cable weight, lb/ft0.1350.1420.1500.157
Min bending radius, in9.74410.03910.33510.689

At Customer’s request Incab can provide specifications for any range of fiber optic cable.

Operation parameters
Operation temperature range*-60°С…+70°С
Installation temperature range-30°С…+50°С
Transportation and storage temperature range-60°С…+70°С
Min bending radius15x cable diameter
Life time25 years
Warranty lifetimeas specified in the supply agreement,min 2 years

* Operation temperature range can be increased on request.

Options

Aerial self-supporting cable can be manufactured in versions (A)-HF (for lead-in into a building), and E.


(A)-HF — cable jacket is made of a polymer material, flame retardant in a group laying, with low smoke emission, halogen-free.


E — cable jacket is made of a tracking-resistant material, can be used in case of exposure of the cable to the electric field with a potential above 12 kV.