InAir ADSS Standard Fiberglass

Applied for aerial installation on distribution and high voltage power lines, as well as railway catenary.

Applied inside buildings, in ducts, trays, blocks, tunnels, and collecting channels, on bridges, with a small risk of rodents’ attacks or in protecting tubes.

Also applied for direct-buried installation in protecting tubes.

+

InAir ADSS Standard Fiberglass

(Multi-Tube Fiberglass Double Jacket Cable)

  • 7
    Jacket
  • 6
    Reinforcing member – fiberglass yarns
  • 8
    Ripcord
  • 5
    Inner jacket
  • 4
    Water-blocking yarns
  • 3
    PBT loose tube filled with water-swellable gel
  • 2
    Optical fiber
  • 1
    Central strength member (dielectric fiberglass reinforced plastic)

Advantages

All-dielectric construction.

Wide temperature range, installation temperature down to -30C°

In duct application fiberglass yarns protect the cable from rodents (medium protection level).

Cost-effective solution for city trunk lines.

Application up to 15 kN with span lengths up to 300 m.

Aerial suspension on 35 kV power lines and above.

Features

Optical Fiber Specifications
Optical Fiber Color Identification


Crush for all cables in the group — from 171 lb/in
Tensile strength — 899 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5000.5240.5470.571
Cable weight, lb/ft0.0840.0920.1000.107
Min bending radius, in7.5007.8548.2098.563



Tensile strength — 1349 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5000.5240.5470.571
Cable weight, lb/ft0.0840.0920.1000.107
Min bending radius, in7.5007.8548.2098.563



Tensile strength — 1574 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5000.5240.5470.571
Cable weight, lb/ft0.0840.0920.1000.107
Min bending radius, in7.5007.8548.2098.563



Tensile strength — 1798 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5080.5280.5470.571
Cable weight, lb/ft0.0870.0930.1000.107
Min bending radius, in7.6187.9138.2098.563



Tensile strength — 2248 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (6х24)
Cable diameter, in0.5160.5360.5590.583
Cable weight, lb/ft0.0910.0990.1040.112
Min bending radius, in7.7368.0918.3868.740



Tensile strength — 2248 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (9х16)
Cable diameter, in0.5310.5510.5630.591
Cable weight, lb/ft0.0980.1030.1050.117
Min bending radius, in7.9728.2688.4458.858



Tensile strength — 3372 lb


Fiber countup to 48 (6х8)up to 72 (6х12)up to 96 (6х16)up to 144 (9х16)
Cable diameter, in0.5510.5710.5830.606
Cable weight, lb/ft0.1060.1120.1150.125
Min bending radius, in8.2688.5638.7409.094

At Customer’s request Incab can provide specifications for any range of fiber optic cable.

Operation parameters
Operation temperature range*-60°С…+70°С
Installation temperature range-30°С…+50°С
Transportation and storage temperature range-60°С…+70°С
Min bending radius15x cable diameter
Life time25 years
Warranty lifetimeas specified in the supply agreement,min 2 years

* Operation temperature range can be increased on request.

Options

Aerial self-supporting cable can be manufactured in versions (A)-HF (for lead-in into a building), and E.


(A)-HF — cable jacket is made of a polymer material, flame retardant in a group laying, with low smoke emission, halogen-free.


E — cable jacket is made of a tracking-resistant material, can be used in case of exposure of the cable to the electric field with a potential above 12 kV.