InAir Figure 8

InAir Figure 8 Stainless Steel Tube part no.

Applied for aerial installations: on power lines, lamp posts, between buildings and constructions. Suitable for aerial installation on transmission equipment and power facilities in dielectric package.

1

Optical fiber

2

Stainless steel tube filled with water-blocking gel

3

Jacket

4

Steel wire

Up to 48 fibers in a tube

High crush resistance

Max. installation tension 899 lb
Crush — from 400 lb/in
Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, in 0 0.22 0.236 0.248
Max overall cable size, in 0 0.48 0.496 0.508
Equivalent cable diameter, in 0 0.295 0.311 0.319
Cable weight, lb/ft 0.064 0.063 0.066 0.068
Max. installation tension 1349 lb
Crush — from 400 lb/in
Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, in 0 0.22 0.236 0.248
Max overall cable size, in 0 0.492 0.508 0.52
Equivalent cable diameter, in 0 0.299 0.315 0.323
Cable weight, lb/ft 0.07 0.069 0.073 0.075
Start shopping
Operation temperature -76°F … 158°F
Installation temperature -22°F … 122°F
Transportation and storage temperature -76°F … 158°F
Minimum bending radius 15x cable diameter
Life time 25 years
Warranty as specified in the supply agreement, min 2 years