InAir Self-Supporting

InAir ADSS Standard Fiberglass (Multi-Tube Fiberglass Double Jacket Cable) part no.
0398

Designed for aerial installation on transmission towers, high voltage power lines and railway catenary; highly resistant to electromagnetic effect.

1

Central strength member (dielectric fiberglass reinforced plastic)

2

Optical fiber

3

PBT loose tube filled with water-blocking gel

4

Water-swellable yarns

5

Inner jacket

6

Reinforcing member – fiberglass yarns

7

Jacket

8

Ripcord

All-dielectric construction – fully resistant to electromagnetic fields

Wide range of operating temperatures. Installation temperature down to -22 F

In duct applications fiberglass yarns protect the cable from rodents (medium protection level)

Cost-effective solution for city trunk lines

Aerial installation on distribution and transmission lines up to 138 kV

Maximum rated design loads up to 3372 lb with span lengths up to 984 ft

Maximum rated design loads (MRDL) 899 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.492 0.516 0.539 0.563
Cable weight, lb/ft 0.082 0.09 0.097 0.105
Min bending radius, in 7.382 7.736 8.091 8.445
Maximum rated design loads (MRDL) 1349 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.492 0.516 0.539 0.563
Cable weight, lb/ft 0.083 0.09 0.097 0.105
Min bending radius, in 7.382 7.736 8.091 8.445
Maximum rated design loads (MRDL) 1574 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.5 0.52 0.539 0.563
Cable weight, lb/ft 0.086 0.092 0.097 0.105
Min bending radius, in 7.5 7.795 8.091 8.445
Maximum rated design loads (MRDL) 1798 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.504 0.524 0.543 0.571
Cable weight, lb/ft 0.087 0.093 0.099 0.108
Min bending radius, in 7.559 7.854 8.15 8.563
Maximum rated design loads (MRDL) 2248 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.516 0.535 0.551 0.579
Cable weight, lb/ft 0.092 0.098 0.103 0.113
Min bending radius, in 7.736 8.031 8.268 8.681
Maximum rated design loads (MRDL) 2698 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (9х16)
Cable diameter, in 0.524 0.543 0.563 0.591
Cable weight, lb/ft 0.098 0.103 0.109 0.118
Min bending radius, in 7.854 8.15 8.445 8.858
Maximum rated design loads (MRDL) 3372 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (9х16)
Cable diameter, in 0.547 0.563 0.579 0.606
Cable weight, lb/ft 0.106 0.11 0.116 0.126
Min bending radius, in 8.209 8.445 8.681 9.094
Start shopping
Operation temperature -76°F … 158°F
Installation temperature -22°F … 122°F
Transportation and storage temperature -76°F … 158°F
Minimum bending radius 15x cable diameter
Life time 25 years
Warranty as specified in the supply agreement, min 2 years