InSky OPGW
Used by electric utilities on transmission lines with the voltage of 35 kV and higher for creating optical communication lines and protecting the power lines from lightning strikes.
InAir ADSS
Applied for aerial installation on distribution and power transmission lines for building long distance optical communication systems.
Specialty Cable
Used for distributed fiber optic sensing in different applications.
InFire Rated
Used for indoor and outdoor applications where fire resistance is a must. Remain functional under direct flame for at least 180 minutes.
InDuct
Applied in ducts, conduits and trays with no risk of rodent attacks. Can also be lashed.
InArmor
Designed for high reliability in harsh environments with potential mechanical impact. Applied in all ground types, swamps, and harsh rivers.
BlownIn
Designed for air blowing in ducts and microducts for building reliable underground communication networks.
InWater
Designed for underwater application with increased crush and tensile loads.
InAir Figure 8
Used for cost-effective one-step aerial installation mostly in rural areas where the spans between poles are not long .
InControl
Applied in substations for control purposes.
InHome FTTH
Used to create communication lines between the common distribution box and a location inside the building (including vertical runs), between entrances or corridors in office buildings.
InDrop FTTH
Applied for aerial installation on transmission towers, lightning poles, between buildings and structures for communication networks in rural areas.
Incab uses improved single-mode fiber – Corning® SMF-28® Ultra.
It has the following advantages compared to the standard fiber*:
— Signal attenuation at least 10% lower than that of standard fiber*
— 10 times more resistant to bending than standard fiber*
— 100% compatible with other single-mode fibers
*Standard fiber Corning® SMF28e+®
By default we use Corning optical fiber in manufacturing, however, at the client’s request, we can produce cable with fiber from another supplier.
Fiber type | U | U | ULL | G.655.D | G.654.E | G.657.A2 | G.657.B3 | ||
Product name | Corning® SMF-28® Ultra | Corning® SMF-28® Ultra 200 | Corning® SMF-28® ULL | Corning® LEAF® | Corning® TXF® | Corning® ClearCurve® LBL | Corning® ClearCurve® ZBL | ||
ITU-T recommendation | G.652.D / G.657.A1 | G.652.D / G.657.A1 | G.652.B / G.654.C | G.655.D | G.654.E | G.652.D / G.657.A2/B2 | G.657.B3 | ||
Dimensional Specifications | |||||||||
Core-Clad Concentricity | 0.5 | 0.5 | 0.5 | 0.5 | 0.8 | 0.5 | 0.5 | ||
Cladding Diameter | 125±0.7 | 125±0.7 | 125±0.7 | 125±0.7 | 125±0.7 | 125±0.7 | 125±0.7 | ||
Cladding Non-Circularity | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | ||
Coating Diameter | 242±5 | 200±5 | 242±5 | 242±5 | 242±5 | 242±5 | 242±5 | ||
Transmission Specifications | |||||||||
Wavelength, nm | 1310 – 1625 | 1310 – 1625 | 1310 – 1625 | 1550 | 1550 – 1625 | 1310 – 1625 | 1310 – 1625 | ||
Maximum Attenuation (dB/km) | |||||||||
1310 nm wavelength | 0.32 | 0.32 | 0.31 | – | – | 0.35 | 0.35 | ||
1383 nm wavelength | 0.32 | 0.32 | — | 0.40 | — | 0.35 | 0.35 | ||
1490 nm wavelength | 0.21 | 0.21 | — | — | — | 0.24 | 0.24 | ||
1550 nm wavelength | 0.18 | 0.18 | 0.17 | 0.19 | 0.17 | 0.20 | 0.20 | ||
1625 nm wavelength | 0.20 | 0.20 | 0.20 | 0.21 | 0.19 | 0.23 | 0.23 | ||
Dispersion ps/(nm*km) | |||||||||
1550 nm wavelength | 18 | 18 | 18 | 4 | 23 | 18 | 18 | ||
1625 nm wavelength | 22 | 22 | 22 | 10 | 29 | 23 | 23 | ||
Polarization Mode Dispersion (PMD), ps/√km | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 | ||
Zero Dispersion | 0.092 | 0.092 | 0.07 | 0.092 | 0.092 | — | |||
Zero Dispersion Wavelength, nm | 1304…1324 | 1304…1324 | 1300…1324 | — | 1304…1324 | 1304…1324 | — | ||
Cable Cutoff Wavelength, nm | 1260 | 1260 | 1260 | 1360 | 1520 | 1260 | 1260 | ||
Mode-Field Diameter, (μm) | |||||||||
1310 nm wavelength | 9.2±0.4 | 9.2±0.4 | 9.2±0.5 | — | — | 8.6±0.4 | 8.6±0.4 | ||
1550 nm wavelength | 10.4±0.5 | 10.4±0.5 | 10.5±0.5 | 9.6±0.4 | 12.4±0.5 | 9.6±0.5 | 9.65±0.5 | ||
Macrobend Loss, dB, λ=1550 nm/1625 nm | |||||||||
(1 turn х R16.0 mm), dB | — | — | 0.1/— | 0.5/0.5 | — | — | — | ||
(1 turn х R10.0 mm), dB | 0.5/1.5 | 0.5/1.5 | — | — | — | — | — | ||
(1 turn х R7.5mm), dB | — | — | — | — | — | 0.4/0.8 | — | ||
(1 turn х R5.0 mm), dB | — | — | — | — | — | — | 0.1/0.3 | ||
(100 turns х R30 mm), dB | — | — | —/0.05 | 0.05/0.05 | 0.1/0.1 | — | — |
Fiber type | ОМ2 | ОМ3 | ОМ4 | ОМ5 | ОМ1 |
Product name | Corning® ClearCurve® OM2 | Corning® ClearCurve® OM3 | Corning® ClearCurve® OM4 | Corning® ClearCurve® OM5 | Corning® InfiniCor® 300 |
Standard | ITU-T G.651 | ITU-T G.651 | ITU-T G.651 | ITU-T G.651 | IEC 60793-2-10 |
Dimensional Specifications | |||||
Core Diameter | 50.0±2.5 | 50.0±2.5 | 50.0±2.5 | 50.0±2.5 | 62.5±3.0 |
Core-Clad Concentricity | 1.5 | ||||
Cladding Diameter | 125±1 | 125±1 | 125±1 | 125±1 | 125±2 |
Cladding Non-Circularity | 1 | ||||
Coating Diameter | 242±5 | ||||
Maximum Attenuation (dB/km) | |||||
850 nm wavelength | 2.3 | 2.3 | 2.3 | 2.3 | 2.9 |
953 nm wavelength | – | – | – | 1.7 | – |
1300 nm wavelength | 0.6 | ||||
Numerical Aperture | 0.200±0.015 | 0.200±0.015 | 0.200±0.015 | 0.200±0.015 | 0.275±0.015 |
Overfilled Bandwidth (MHz * km) | |||||
850 nm wavelength | 700 | 1500 | 3500 | 3500 | 200 |
953 nm wavelength | – | – | – | 1850 | – |
1300 nm wavelength | 500 | ||||
Effective Group Index of Retraction | |||||
850 nm wavelength | 1.482 | 1.482 | 1.482 | 1.482 | 1.496 |
1300 nm wavelength | 1.477 | 1.477 | 1.477 | 1.477 | 1.491 |
Attenuation to macrobending (2 turns on a bend former, radius of 15 mm), dB: | |||||
at a wavelength of 850 nm | 0.1 | 0.1 | 0.1 | 0.1 | – |
at a wavelength of 1300 nm | 0.3 | 0.3 | 0.3 | 0.3 | – |
Attenuation to macrobending (2 turns on a bend former, radius of 7.5 mm), dB: | |||||
at a wavelength of 850 nm | 0.2 | 0.2 | 0.2 | 0.2 | – |
at a wavelength of 1300 nm | 0.5 | 0.5 | 0.5 | 0.5 | – |