InDuct Standard

Applied in ducts, trays, blocks, tunnels, collecting channels, with a risk of rodents’ attacks.

Applied for direct buried installation if the mechanical impact does not exceed the specified limits.

Also applied for installation on bridges.

+

InDuct Standard

(Multi-Tube Single Armor Double Jacket Cable)

  • 8
    Polymer jacket
  • 7
    Corrugated steel tape armor
  • 6
    Inner jacket
  • 5
    Water blocking yarns
  • 4
    Inter-tube water-swellable gel
  • 3
    PBT loose tube filled with water-swellable gel
  • 2
    Optic fiber
  • 1
    Central strength member: FRP

Advantages

Armor is a perfect protection from rodents.

Proven reliable design.

Improved reliability due to inner jacketing.

Resistance to crushing loads from 0.3 kN/cm.

Allowable tensile strength up to 2.7 kN.

Efficient design.

Features

Optical Fiber Specifications
Optical Fiber Color Identification


Crush — 171 lb/in
Tensile strength — 607 lb


Fiber countup to 48up to 72up to 96up to 144
Cable diameter, in0,4960,5080,5510,587
Cable weight, lb/ft0,1010,1040,1210,136
Min bending radius, in7,4417,6188,2688,799

At Customer’s request Incab can provide specifications for any range of fiber optic cable.

Operation Parameters
Operation temperature range*-50°С…+70°С
Installation temperature range-30°С…+50°С
Transportation and storage temperature range-60°С…+70°С
Min bending radius15x cable diameter
Life time25 years
Warranty lifetimeas specified in the supply agreement,min 2 years

* Operation temperature range can be increased on request.

Options

All cables of this group can be produced in versions H and (A)-HF.


H — cable jacket is made of a polymer material not propagating fire in a single laying.


(A)-HF — cable jacket is made of a polymer material, flame retardant in a group laying, with low smoke emission, halogen-free.