InSky OPGW
Used by electric utilities on transmission lines with the voltage of 35 kV and higher for creating optical communication lines and protecting the power lines from lightning strikes.
InAir ADSS
Applied for aerial installation on distribution and power transmission lines for building long distance optical communication systems.
Specialty Cable
Used for distributed fiber optic sensing in different applications.
InFire Rated
Used for indoor and outdoor applications where fire resistance is a must. Remain functional under direct flame for at least 180 minutes.
InDuct
Applied in ducts, conduits and trays with no risk of rodent attacks. Can also be lashed.
InArmor
Designed for high reliability in harsh environments with potential mechanical impact. Applied in all ground types, swamps, and harsh rivers.
BlownIn
Designed for air blowing in ducts and microducts for building reliable underground communication networks.
InWater
Designed for underwater application with increased crush and tensile loads.
InAir Figure 8
Used for cost-effective one-step aerial installation mostly in rural areas where the spans between poles are not long .
InControl
Applied in substations for control purposes.
InHome FTTH
Used to create communication lines between the common distribution box and a location inside the building (including vertical runs), between entrances or corridors in office buildings.
InDrop FTTH
Applied for aerial installation on transmission towers, lightning poles, between buildings and structures for communication networks in rural areas.
An indoor/outdoor direct buried cable for applications where induced voltages and currents must be eliminated.
Central strength member (fiberglass reinforced plastic)
Optical fiber
PBT loose tube filled with water-blocking gel
Inner jacket made of halogen-free flame-retardant polymer compound
Water-swellable yarns
Armor of fiberglass rods
Fiberglass yarns
Halogen-free jacket
Ripcord
InFire Rated Universal Dielectric cable is designed specifically for elimination of induced voltages and currents. The FRP rods provide strength to the cable and make it perfect for all applications. This design also has a guaranteed 25 year lifespan and the ability to accommodate up to 24 fibers making it an ideal choice for any project requiring steadfast electrical performance and durability.
Maximum rated design tension (MRDT) | 1574 lb (7 kN) | ||
Crush | 228 lb/in (0.4 kN/cm) | ||
Fiber count, up to | 72 (6x12) | 96 (8x12) | 144 (12x12) |
Cable diameter, in | 0.626 | 0.713 | 0.87 |
Cable weight, lb/ft | 0.208 | 0.267 | 0.39 |
Minimum bending radius, in | 9.4 | 10.7 | 13.1 |
Maximum rated design tension (MRDT) | 1574 lb (7 kN) | ||||
Fiber count, up to | 24 | 48 | 72 | 96 | 144 |
Number of loose tubes | 6 | 6 | 6 | 6 | 6 |
Fibers per loose tube | 4 | 8 | 12 | 16 | 24 |
Cable diameter, in | 0.583 | 0.594 | 0.626 | 0.685 | 0.697 |
Cable weight, lb/ft | 0.184 | 0.19 | 0.208 | 0.247 | 0.247 |
Minimum bending radius, in | 8.7 | 8.9 | 9.4 | 10.3 | 10.5 |
Operating temperature | -58°F ... +158°F |
Installation temperature | +14°F ... +122°F |
Transportation and storage temperature | -58°F ... +122°F |
Minimum bending radius | 15 x cable diameter |
Design life | 25 years |