InAir Figure 8

InAir Figure 8 MT GSW part no.
0068
Multi-Tube (MT) Galvanized Steel Wires (GSW)

A figure-8 design for a simple one-step installation in the communications space of distribution lines.

1

Central strength member (dielectric fiberglass reinforced plastic)

2

Optical fiber

3

PBT loose tube filled with water-blocking gel

4

Water-swellable yarns

5

Jacket

6

Steel wire

7

Ripcord

Affordable alternative to InAir ADSS

Low installation cost

Maximum rated design tension 899 lb
Crush — 171 lb/in
External strength member jacket diameter 0.205 in
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable jacket diameter, in 0.339 0.350 0.366 0.386 0.409 0.449 0.543
Maximum overall cable size, in 0.622 0.634 0.650 0.669 0.693 0.732 0.827
Cable weight, lb/ft 0.067 0.068 0.072 0.076 0.084 0.095 0.121
Maximum rated design tension 1349 lb
Crush — 171 lb/in
External strength member jacket diameter 0.229 in
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable jacket diameter, in 0.339 0.350 0.366 0.386 0.409 0.449 0.543
Maximum overall cable size, in 0.646 0.657 0.673 0.693 0.717 0.756 0.850
Cable weight, lb/ft 0.079 0.080 0.084 0.087 0.096 0.106 0.133
Maximum rated design tension 2023 lb
Crush — 171 lb/in
External strength member jacket diameter 0.252 in
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable jacket diameter, in 0.339 0.350 0.366 0.386 0.409 0.449 0.543
Maximum overall cable size, in 0.669 0.681 0.697 0.717 0.740 0.780 0.874
Cable weight, lb/ft 0.092 0.094 0.097 0.101 0.110 0.120 0.147
Maximum rated design tension 2698 lb
Crush — 171 lb/in
External strength member jacket diameter 0.276 in
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable jacket diameter, in 0.339 0.350 0.366 0.386 0.409 0.449 0.543
Maximum overall cable size, in 0.693 0.705 0.720 0.740 0.764 0.803 0.898
Cable weight, lb/ft 0.109 0.110 0.114 0.117 0.126 0.136 0.163
Start shopping
Operating temperature -58°F … +32°F
Installation temperature -22°F … +122°F
Transportation and storage temperature -58°F … +32°F
Minimum bending radius 15x cable diameter
Life time 25 years