InArmor

InArmor+ CT GSW part no.
0477
Central Tube (CT) Galvanized Steel Wires (GSW)

Direct buried cable that can also be installed in ducts.

1

Optical fiber

2

PBT loose tube filled with water-blocking gel

3

Water-blocking gel or water-swellable yarns

4

Armor of galvanized steel wires

5

Polymer jacket

Excellent rodent resistance

Cost-effective design

100% waterproof

Up to 24 fibers

Maximum rated design tension up to 1124 lb

Resistance to crushing load from 400 lb/in

Reduced weight and size

Maximum rated design tension 1124 lb
Crush — 400 lb/in
Fiber count up to 16 up to 24
Cable diameter, in 0.319 0.327
Cable weight, lb/ft 0.078 0.083
Min bending radius, in 4.783 4.902
Operation temperature -58°F … 158°F
Installation temperature -22°F … 122°F
Transportation and storage temperature -58°F … 158°F
Minimum bending radius 15x cable diameter
Life time 25 years