InFire Rated

InFire Rated Dielectric

Fiberglass provides both strength and rodent resistance. Can be used indoors as a breakout cable, or anywhere that fire resistance is a must.

1

Optical fiber

2

Tight-buffer

3

Fiberglass yarns

4

Inner jacket made of halogen-free flame-retardant polymer compound

5

Mica glass tape

6

Fiberglass yarns

7

Halogen-free jacket

8

Ripcord

Remains functional under direct flame for at least 180 minutes

All-dielectric design

Up to 24 fibers

Easy to install

Maximum rated design tension (MRDT) 247 lb (1.1 kN)
Crush 114 lb/in (0.2 kN/cm)
Fiber count, up to 2 4 6 8 12 16 24
Cable diameter, in 0.421 0.445 0.457 0.469 0.5 0.524 0.555
Cable weight, lb/ft 0.097 0.107 0.113 0.117 0.13 0.142 0.157
Minimum bending radius, in 4.2 4.4 4.6 4.7 5 5.2 5.6
Operating temperature -40°F ... +140°F
Installation temperature +14°F ... +122°F
Transportation and storage temperature -58°F ... +122°F
Minimum bending radius 10 x cable diameter
Design life 25 years

Your guiding light
in Incab America universe

×