InSky OPGW
Used by electric utilities on transmission lines with the voltage of 35 kV and higher for creating optical communication lines and protecting the power lines from lightning strikes.
InAir ADSS
Applied for aerial installation on distribution and power transmission lines for building long distance optical communication systems.
Specialty Cable
Used for distributed fiber optic sensing in different applications.
InFire Rated
Used for indoor and outdoor applications where fire resistance is a must. Remain functional under direct flame for at least 180 minutes.
InDuct
Applied in ducts, conduits and trays with no risk of rodent attacks. Can also be lashed.
InArmor
Designed for high reliability in harsh environments with potential mechanical impact. Applied in all ground types, swamps, and harsh rivers.
BlownIn
Designed for air blowing in ducts and microducts for building reliable underground communication networks.
InWater
Designed for underwater application with increased crush and tensile loads.
InAir Figure 8
Used for cost-effective one-step aerial installation mostly in rural areas where the spans between poles are not long .
InControl
Applied in substations for control purposes.
InHome FTTH
Used to create communication lines between the common distribution box and a location inside the building (including vertical runs), between entrances or corridors in office buildings.
InDrop FTTH
Applied for aerial installation on transmission towers, lightning poles, between buildings and structures for communication networks in rural areas.
Tight-buffered break-out cable for inside buildings and in equipment trays.
Optical fiber
Tight-buffer
Reinforcing elements — aramid yarns
Halogen-free flame-retardant jacket
Ripcord
InHome Distribution TB is a tight-buffered break-out cable for inside buildings and in equipment trays. Versatile indoor-outdoor application makes this cable a perfect solution for offices and data centers while building broadband networks. It is flexible enough and can be easily terminated.
This design is all-dielectric, UV-resistant and flame-retardant. In case of applying fiberglass yarns, it can have moderate rodent resistance.
InHome Distribution TB typically consists of a bundle of tight-buffered fibers. Fiberglass or aramid yarns are laid over the bundle of fibers. Outer jacket is made of halogen-free flame-retardant material.
This tight-buffer cable can have up to 48 fibers though different combinations of fiber counts and loose tubes in a cable are available on request.
InHome Distribution TB’s maximum operation tension can reach up to 180 lb (0.8 kN) and maximum installation tension — up to 360 lb (1.6 kN). Its resistance to crushing load can be up to 114 lb/in (0.2 kN/cm). It has a wide range of operating and installation temperatures from +14°F to +122°F (operating temperature range can be increased on request).
Also check how this FTTH distribution cable can be deployed in FTTH system.
Maximum operation tension, lb | 90 | |||||||||
Maximum installation tension, lb | 180 | |||||||||
Crush | 57 lb/in (0.1 kN/cm) | |||||||||
Fiber count, up to | 2 | 4 | 6 | 8 | 12 | 16 | 24 | 32 | 36 | 48 |
Cable diameter, in | 0.201 | 0.213 | 0.224 | 0.24 | 0.268 | 0.291 | 0.327 | 0.406 | 0.425 | 0.472 |
Cable weight, lb/ft | 0.019 | 0.021 | 0.024 | 0.027 | 0.033 | 0.039 | 0.049 | 0.062 | 0.067 | 0.08 |
Minimum bending radius, in | 2 | 2.1 | 2.2 | 2.4 | 2.7 | 2.9 | 3.3 | 4.1 | 4.3 | 4.7 |
Maximum operation tension, lb | 180 | |||||||||
Maximum installation tension, lb | 360 | |||||||||
Crush | 114 lb/in (0.2 kN/cm) | |||||||||
Fiber count, up to | 2 | 4 | 6 | 8 | 12 | 16 | 24 | 32 | 36 | 48 |
Cable diameter, in | 0.217 | 0.228 | 0.236 | 0.248 | 0.272 | 0.295 | 0.335 | 0.413 | 0.433 | 0.476 |
Cable weight, lb/ft | 0.022 | 0.024 | 0.027 | 0.029 | 0.035 | 0.04 | 0.051 | 0.064 | 0.069 | 0.082 |
Minimum bending radius, in | 2.2 | 2.3 | 2.4 | 2.5 | 2.7 | 3 | 3.3 | 4.1 | 4.3 | 4.8 |
Operating temperature | +14°F ... +122°F |
Installation temperature | +14°F ... +122°F |
Transportation and storage temperature | -58°F ... +122°F |
Minimum bending radius | 10 x cable diameter |
Design life | 25 years |
Operating temperature | +14°F ... +122°F |
Installation temperature | +14°F ... +122°F |
Transportation and storage temperature | -58°F ... +122°F |
Minimum bending radius | 10 x cable diameter |
Design life | 25 years |
Warranty period of operation | определяется договором поставки, но не менее двух лет empty |