InHome FTTH

InHome Distribution TB Distribution tight-buffered (TB)

Tight-buffered break-out cable for inside buildings and in equipment trays.

1

Optical fiber

2

Tight-buffer

3

Reinforcing elements — aramid yarns

4

Halogen-free flame-retardant jacket

5

Ripcord

Up to 48 fibers

Easy termination

More flexible compared to Riser Cable

Flame-retardant

UV-resistant

All-dielectric design

Perfect solution for offices and data centers

InHome Distribution TB is a tight-buffered break-out cable for inside buildings and in equipment trays. Versatile indoor-outdoor application makes this cable a perfect solution for offices and data centers while building broadband networks. It is flexible enough and can be easily terminated.

This design is all-dielectric, UV-resistant and flame-retardant. In case of applying fiberglass yarns, it can have moderate rodent resistance.

InHome Distribution TB typically consists of a bundle of tight-buffered fibers. Fiberglass or aramid yarns are laid over the bundle of fibers. Outer jacket is made of halogen-free flame-retardant material.

This tight-buffer cable can have up to 48 fibers though different combinations of fiber counts and loose tubes in a cable are available on request.

InHome Distribution TB’s maximum operation tension can reach up to 180 lb (0.8 kN) and maximum installation tension — up to 360 lb (1.6 kN). Its resistance to crushing load can be up to 114 lb/in (0.2 kN/cm). It has a wide range of operating and installation temperatures from +14°F to +122°F (operating temperature range can be increased on request).

Also check how this FTTH distribution cable can be deployed in FTTH system.

Indoor
Maximum operation tension, lb 90
Maximum installation tension, lb 180
Crush 57 lb/in (0.1 kN/cm)
Fiber count, up to 2 4 6 8 12 16 24 32 36 48
Cable diameter, in 0.201 0.213 0.224 0.24 0.268 0.291 0.327 0.406 0.425 0.472
Cable weight, lb/ft 0.019 0.021 0.024 0.027 0.033 0.039 0.049 0.062 0.067 0.08
Minimum bending radius, in 2 2.1 2.2 2.4 2.7 2.9 3.3 4.1 4.3 4.7
Indoor and Outdoor
Maximum operation tension, lb 180
Maximum installation tension, lb 360
Crush 114 lb/in (0.2 kN/cm)
Fiber count, up to 2 4 6 8 12 16 24 32 36 48
Cable diameter, in 0.217 0.228 0.236 0.248 0.272 0.295 0.335 0.413 0.433 0.476
Cable weight, lb/ft 0.022 0.024 0.027 0.029 0.035 0.04 0.051 0.064 0.069 0.082
Minimum bending radius, in 2.2 2.3 2.4 2.5 2.7 3 3.3 4.1 4.3 4.8
Operating temperature +14°F ... +122°F
Installation temperature +14°F ... +122°F
Transportation and storage temperature -58°F ... +122°F
Minimum bending radius 10 x cable diameter
Design life 25 years
Operating temperature +14°F ... +122°F
Installation temperature +14°F ... +122°F
Transportation and storage temperature -58°F ... +122°F
Minimum bending radius 10 x cable diameter
Design life 25 years
Warranty period of operation определяется договором поставки, но не менее двух лет empty