InSky OPGW
Used by electric utilities on transmission lines with the voltage of 35 kV and higher for creating optical communication lines and protecting the power lines from lightning strikes.
InAir ADSS
Applied for aerial installation on distribution and power transmission lines for building long distance optical communication systems.
Specialty Cable
Used for distributed fiber optic sensing in different applications.
InFire Rated
Used for indoor and outdoor applications where fire resistance is a must. Remain functional under direct flame for at least 180 minutes.
InDuct
Applied in ducts, conduits and trays with no risk of rodent attacks. Can also be lashed.
InArmor
Designed for high reliability in harsh environments with potential mechanical impact. Applied in all ground types, swamps, and harsh rivers.
BlownIn
Designed for air blowing in ducts and microducts for building reliable underground communication networks.
InWater
Designed for underwater application with increased crush and tensile loads.
InAir Figure 8
Used for cost-effective one-step aerial installation mostly in rural areas where the spans between poles are not long .
InControl
Applied in substations for control purposes.
InHome FTTH
Used to create communication lines between the common distribution box and a location inside the building (including vertical runs), between entrances or corridors in office buildings.
InDrop FTTH
Applied for aerial installation on transmission towers, lightning poles, between buildings and structures for communication networks in rural areas.
A great solution for short and medium spans. It's less expensive than comparable cables with aramid and provides a degree of rodent resistance.
Central strength member (dielectric fiberglass reinforced plastic)
Optical fiber
PBT loose tube filled with water-blocking gel
Water-swellable yarns
Inner jacket
Reinforcing member – fiberglass yarns
Jacket
Ripcord
Ripcord
Ripcord
InAir ADSS FiberGlass DJ is a great and cost-effective fiberglass double jacket cable for short and medium spans up to 984 ft making it applicable for city trunk lines. It’s less expensive than cables with aramid yarns and provides a degree of rodent resistance due to fiberglass yarns. With a track-resistance jacket, it can be used in electric fields up to 25 kV without causing surface discharges. Its maximum rated design tension can be up to 3,372 lb. It also has a wide range of operating temperatures from -76°F to +158°F and installation temperatures from -22°F to +158°F.
Check how this aerial DJ cable can be deployed in FTTH system.
Visit our Configurator ACES: Advanced Cable Engineering System, a unique software tool to help engineers select the optimal ADSS design along with the associated accessories, including dead ends, suspensions, down leads, splice enclosures, and dampers. Use ACES SPOT for calculation of space potential around overhead transmission lines with ADSS cables and for choosing the optimal ADSS cable attachment point on the tower. Go for ACES CATS for simple calculations of tension and sags.
Maximum rated cable load (MRCL), lb | 899 | ||
Crush | 126 lb/in (0.22 kN/cm) | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, in | 0.516 | 0.594 | 0.732 |
Cable weight, lb/ft | 0.087 | 0.111 | 0.169 |
Minimum bending radius, in | 7.8 | 8.9 | 11 |
Maximum rated cable load (MRCL), lb | 1349 | ||
Crush | 126 lb/in (0.22 kN/cm) | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, in | 0.52 | 0.598 | 0.732 |
Cable weight, lb/ft | 0.089 | 0.113 | 0.169 |
Minimum bending radius, in | 7.8 | 9 | 11 |
Maximum rated cable load (MRCL), lb | 1798 | ||
Crush | 126 lb/in (0.22 kN/cm) | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, in | 0.531 | 0.606 | 0.74 |
Cable weight, lb/ft | 0.095 | 0.119 | 0.173 |
Minimum bending radius, in | 8 | 9.1 | 11.1 |
Maximum rated cable load (MRCL), lb | 2248 | ||
Crush | 126 lb/in (0.22 kN/cm) | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, in | 0.543 | 0.618 | 0.748 |
Cable weight, lb/ft | 0.101 | 0.124 | 0.179 |
Minimum bending radius, in | 8.2 | 9.3 | 11.2 |
Maximum rated cable load (MRCL), lb | 2698 | ||
Crush | 126 lb/in (0.22 kN/cm) | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, in | 0.575 | 0.638 | 0.764 |
Cable weight, lb/ft | 0.114 | 0.134 | 0.187 |
Minimum bending radius, in | 8.6 | 9.6 | 11.5 |
Maximum rated cable load (MRCL), lb | 3372 | ||
Crush | 126 lb/in (0.22 kN/cm) | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, in | 0.594 | 0.657 | 0.776 |
Cable weight, lb/ft | 0.124 | 0.146 | 0.197 |
Minimum bending radius, in | 8.9 | 9.9 | 11.7 |
Operating temperature |
-58°F ... +158°F * -76°F ... +158°F upon request |
Installation temperature | -22°F ... +158°F |
Transportation and storage temperature | -58°F ... +158°F |
Minimum bending radius | 15 x cable diameter |
Design life | 25 years |
Your guiding light
in Incab America universe