InAir ADSS

InAir ADSS All-Dielectric Self-Supporting (ADSS)

A cost-effective solution for use on short and medium spans. It will have a smaller diameter and be lighter compared to a double jacket design.

1

Central strength member (FRP rod)

2

Optical fiber

3

Dry loose tube

4

Water-swellable yarns

4

Water-swellable yarns

5

Reinforcing member – aramid yarns

6

Jacket

7

Ripcord

All-dielectric design

Dry design – easy to strip

Low susceptibility to ice and wind loads

Reduced weight and size

Cost-effective design

Aerial installation on distribution and transmission lines up to 34.5 kV

Maximum rated design tension up to 2248 lb with span lengths up to 656 ft

Wide range of operating temperatures. Installation temperature down to -22°F

Gel-filled option available

InAir ADSS (All-Dielectric Self-Supporting) is a cost-effective self-supporting aerial cable for use on short and medium spans up to 656 ft with maximum rated design tension up to 2,248 lb. This design is dry making it easy to strip. It has a wide range of operating temperatures from -76°F to +158°F and installation temperatures from -22°F to +158°F. It also features reduced weight and size and low susceptibility to ice and wind loads.

Check how this multi tube single jacket self-supporting cable can be deployed in FTTH system.

Visit our ACES: Advanced Cable Engineering System: it is a unique software tool which helps engineers select the optimal ADSS design along with the associated accessories. ACES ADSS also helps engineers and planners prepare cost estimates, generate a complete bill of materials, determine reel lengths, and plan logistics. ACES SPOT makes calculation of space potential around overhead transmission lines with ADSS cables as well as choosing the optimal ADSS cable attachment point on the tower quite easy. Use ACES CATS for simple calculations of tension and sags.

Maximum rated design tension (MRDT) 899 lb (4 kN)
Crush 126 lb/in (0.22 kN/cm)
Fiber count, up to 72 (6x12) 96 (8x12) 144 (12x12)
Cable diameter, in 0.453 0.524 0.728
Cable weight, lb/ft 0.057 0.075 0.143
Minimum bending radius, in 6.8 7.9 10.9
Maximum rated design tension (MRDT) 1349 lb (6 kN)
Crush 126 lb/in (0.22 kN/cm)
Fiber count, up to 72 (6x12) 96 (8x12) 144 (12x12)
Cable diameter, in 0.457 0.528 0.728
Cable weight, lb/ft 0.059 0.077 0.144
Minimum bending radius, in 6.9 7.9 10.9
Maximum rated design tension (MRDT) 1798 lb (8 kN)
Crush 126 lb/in (0.22 kN/cm)
Fiber count, up to 72 (6x12) 96 (8x12) 144 (12x12)
Cable diameter, in 0.461 0.531 0.732
Cable weight, lb/ft 0.061 0.079 0.146
Minimum bending radius, in 6.9 8 11
Maximum rated design tension (MRDT) 2248 lb (10 kN)
Crush 126 lb/in (0.22 kN/cm)
Fiber count, up to 72 (6x12) 96 (8x12) 144 (12x12)
Cable diameter, in 0.469 0.535 0.732
Cable weight, lb/ft 0.064 0.081 0.148
Minimum bending radius, in 7 8 11
Operating temperature -40°F ... +158°F
Installation temperature -22°F ... +158°F
Transportation and storage temperature -58°F ... +158°F
Minimum bending radius 15 x cable diameter
Design life 25 years