InSky OPGW
Used by electric utilities on transmission lines with the voltage of 35 kV and higher for creating optical communication lines and protecting the power lines from lightning strikes.
InAir ADSS
Applied for aerial installation on distribution and power transmission lines for building long distance optical communication systems.
Specialty Cable
Used for distributed fiber optic sensing in different applications.
InFire Rated
Used for indoor and outdoor applications where fire resistance is a must. Remain functional under direct flame for at least 180 minutes.
InDuct
Applied in ducts, conduits and trays with no risk of rodent attacks. Can also be lashed.
InArmor
Designed for high reliability in harsh environments with potential mechanical impact. Applied in all ground types, swamps, and harsh rivers.
BlownIn
Designed for air blowing in ducts and microducts for building reliable underground communication networks.
InWater
Designed for underwater application with increased crush and tensile loads.
InAir Figure 8
Used for cost-effective one-step aerial installation mostly in rural areas where the spans between poles are not long .
InControl
Applied in substations for control purposes.
InHome FTTH
Used to create communication lines between the common distribution box and a location inside the building (including vertical runs), between entrances or corridors in office buildings.
InDrop FTTH
Applied for aerial installation on transmission towers, lightning poles, between buildings and structures for communication networks in rural areas.
This design combines enhanced optical reliability with the highest degree of rodent resistance available in an all-dielectric cable. It also can be used as an all-dielectric direct buried cable solution.
Central strength member (fiberglass reinforced plastic)
Optical fiber
PBT loose tube filled with water-blocking gel
Water-swellable yarns
Inner jacket
Water-swellable yarns
Fiberglass rods
Jacket
Ripcord
Ripcord
Rodent gnawing damage is a very common problem in the USA, and it might be both extremely costly and very dangerous. InAir ADSS FRP Defender is a multi tube fiberglass rods cable which is specifically designed to solve the rodent problem. This design has three lines of defense. The first line is an anti-rodent additive in the outer jacket to discourage chewing. The second one is an FRP rod to stop chewing if they do. Finally, an inner jacket ensures that the optical core is protected from water ingress. Its maximum rated design tension can be up to 4,496 lb. And, even though it is “InAir”, it can also be deployed underground as an all-dielectric direct bury solution.
Check how this defender ADSS cable can be deployed in FTTH systems.
Visit our ACES: Advanced Cable Engineering System, a unique software tool where you can select the optimal cable design along with the associated accessories, estimate costs, generate datasheets, calculate space potential or tension and sags, and more! Online, simple, and free!
Maximum rated cable load (MRCL), lb | 1574 | |||
Crush | 228 lb/in (0.4 kN/cm) | |||
Fiber count, up to | 48 (4х12) | 72 (6х12) | 96 (4х24) | 144 (6х24) |
Cable diameter, in | 0.512 | 0.555 | 0.567 | 0.638 |
Cable weight, lb/ft | 0.097 | 0.115 | 0.117 | 0.156 |
Minimum bending radius, in | 7.7 | 8.3 | 8.5 | 9.6 |
Maximum rated cable load (MRCL), lb | 3597 | |||
Crush | 228 lb/in (0.4 kN/cm) | |||
Fiber count, up to | 48 (4х12) | 72 (6х12) | 96 (4х24) | 144 (6х24) |
Cable diameter, in | 0.598 | 0.634 | 0.638 | 0.685 |
Cable weight, lb/ft | 0.146 | 0.164 | 0.161 | 0.181 |
Minimum bending radius, in | 9 | 9.5 | 9.6 | 10.3 |
Maximum rated cable load (MRCL), lb | 4496 | |||
Crush | 228 lb/in (0.4 kN/cm) | |||
Fiber count, up to | 48 (4х12) | 72 (6х12) | 96 (4х24) | 144 (6х24) |
Cable diameter, in | 0.638 | 0.665 | 0.669 | 0.693 |
Cable weight, lb/ft | 0.171 | 0.185 | 0.182 | 0.19 |
Minimum bending radius, in | 9.6 | 10 | 10 | 10.4 |
Operating temperature |
-58°F ... +158°F * -76°F ... +158°F upon request |
Installation temperature | -22°F ... +158°F |
Transportation and storage temperature | -58°F ... +158°F |
Minimum bending radius | 15 x cable diameter |
Design life | 25 years |
Your guiding light
in Incab America universe