InAir Self-Supporting

InAir ADSS Light Fiberglass (Multi-Tube Fiberglass Single Jacket Cable) part no.
0399

Designed for aerial installation on transmission towers, high voltage power lines and railway catenary; highly resistant to electromagnetic effect.

1

Central strength member (dielectric fiberglass reinforced plastic)

4

Water blocking yarns

2

Optical fiber

3

PBT loose tube filled with water-blocking gel

4

Water-swellable yarns

5

Reinforcing member – fiberglass yarns

6

Jacket

7

Ripcord

All-dielectric construction – fully resistant to electromagnetic fields

Reduced weight and size. Low ice and wind load

Dry construction – easy to strip

Cost-effective solution for city trunk lines

Aerial installation on distribution and transmission lines up to 138kV

Maximum rated design loads up to 2248 lb with span lengths up to 656 ft

Wide range of operating temperatures. Installation temperature down to -22 F

Maximum rated design loads (MRDL) 450 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.331 0.354 0.39 0.445
Cable weight, lb/ft 0.037 0.042 0.049 0.063
Min bending radius, in 4.961 5.315 5.846 6.673
Maximum rated design loads (MRDL) 674 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.366 0.39 0.413 0.445
Cable weight, lb/ft 0.047 0.051 0.056 0.063
Min bending radius, in 5.492 5.846 6.201 6.673
Maximum rated design loads (MRDL) 899 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.437 0.461 0.488 0.508
Cable weight, lb/ft 0.065 0.07 0.077 0.083
Min bending radius, in 6.555 6.909 7.323 7.618
Maximum rated design loads (MRDL) 1349 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.441 0.461 0.488 0.508
Cable weight, lb/ft 0.066 0.07 0.077 0.083
Min bending radius, in 6.614 6.909 7.323 7.618
Maximum rated design loads (MRDL) 1574 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.445 0.465 0.488 0.508
Cable weight, lb/ft 0.067 0.071 0.077 0.083
Min bending radius, in 6.673 6.969 7.323 7.618
Maximum rated design loads (MRDL) 1798 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.449 0.469 0.488 0.512
Cable weight, lb/ft 0.069 0.074 0.077 0.085
Min bending radius, in 6.732 7.028 7.323 7.677
Maximum rated design loads (MRDL) 2248 lb
Crush — from 171 lb/in
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, in 0.461 0.48 0.496 0.52
Cable weight, lb/ft 0.075 0.078 0.081 0.088
Min bending radius, in 6.909 7.205 7.441 7.795
Start shopping
Operation temperature -76°F … 158°F
Installation temperature -22°F … 122°F
Transportation and storage temperature -76°F … 158°F
Minimum bending radius 15x cable diameter
Life time 25 years
Warranty as specified in the supply agreement, min 2 years