OPGW/Ground Wire
Applied in the construction of fiber-optic link on overhead transmission lines of 35 kV and more.
InAir Self-Supporting
Applied for aerial installation on distribution and high voltage power lines, as well as railway catenary.
Specialty Cable
For fiber optic monitoring systems.
Fire Rated
Used for stationary installation when the optical fiber needs extra protection from mechanical damages.
InTube
Designed for duct installations Applied in duct, trays, blocks, tunnels, collecting channels, with no risk of rodents’ attacks.Also applied for aerial installation between supports and buildings on external strength members or using the winding method.
InDuct
Applied in ducts, trays, blocks, tunnels, collecting channels, with a risk of rodents’ attacks.
InGround
Applied in harsh environments with potential mechanical impact: in grounds of all the groups, bogs, unnavigable rivers.
InWater
Applied in sea areas (coastal shelf and deep-sea), on navigable rivers, in lakes and water storage basins, in harsh environments, in bogs and unnavigable rivers.
InAir Figure 8
Applied for aerial installations: on power lines, lamp posts, between buildings and constructions. Suitable for aerial installation on transmission equipment and power facilities in dielectric package.
FTTH-Distribution
Applied inside buildings (including vertical runs), in trays, channels, on outer sides of buildings, as well as in duct, in tubes and blocks. Suitable for blowing-in into protecting polyethylene tubes.
FTTH-Subscribers
Applied inside buildings and premises, in trays, cable channels, in duct, tubes and blocks. It is also applied on outer sides of buildings and for optical cords manufacturing.
FTTH-Drop
Applied for aerial installation on transmission towers, lamp posts, between buildings and constructions.
Semi-Finished Products
Steel optical module, clad wire and temporary optical cable.
For aerial installation between buildings and constructions, for cabling into ground, in duct, tubes, tunnels, manifolds, on the bridges and overpasses.
Central strength member (fiberglass reinforced plastic)
Optical fiber
PBT loose tube filled with water-blocking gel
Water-swellable yarns
Inner jacket
Water-swellable yarns
Fiberglass rods
Jacket
Ripcord
Ripcord
Crush — from 228 lb/in | |||||||
Fiber count | up to 16 | up to 32 | up to 48 | up to 64 | up to 72 | up to 96 | up to 144 |
Cable diameter, in | 0.488 | 0.496 | 0.512 | 0.52 | 0.567 | 0.567 | 0.693 |
Cable weight, lb/ft | 0.091 | 0.093 | 0.099 | 0.102 | 0.121 | 0.121 | 0.197 |
Min bending radius, in | 7.323 | 7.441 | 7.677 | 7.795 | 8.504 | 8.504 | 10.394 |
Crush — from 228 lb/in | |||||||
Fiber count | up to 16 | up to 32 | up to 48 | up to 64 | up to 72 | up to 96 | up to 144 |
Cable diameter, in | 0.575 | 0.583 | 0.598 | 0.606 | 0.638 | 0.638 | 0.693 |
Cable weight, lb/ft | 0.141 | 0.143 | 0.151 | 0.153 | 0.167 | 0.167 | 0.197 |
Min bending radius, in | 8.622 | 8.74 | 8.976 | 9.094 | 9.567 | 9.567 | 10.394 |
Crush — from 228 lb/in | |||||||
Fiber count | up to 16 | up to 32 | up to 48 | up to 64 | up to 72 | up to 96 | up to 144 |
Cable diameter, in | 0.614 | 0.622 | 0.638 | 0.646 | 0.669 | 0.669 | 0.693 |
Cable weight, lb/ft | 0.165 | 0.168 | 0.178 | 0.18 | 0.19 | 0.19 | 0.197 |
Min bending radius, in | 9.213 | 9.331 | 9.567 | 9.685 | 10.039 | 10.039 | 10.394 |
Operation temperature | -58°F … 158°F |
Installation temperature | -22°F … 122°F |
Transportation and storage temperature | -76°F … 158°F |
Minimum bending radius | 15x cable diameter |
Life time | 25 years |
Warranty | as specified in the supply agreement, min 2 years |
Useful links:
3D animation
See the steps of producing an optical cable
InAir ADSS Standard Aramid (Multi-Tube Aramid Double Jacket Cable)
InAir ADSS Light Aramid (Multi-Tube Aramid Single Jacket Cable)
InAir ADSS Standard Fiberglass (Multi-Tube Fiberglass Double Jacket Cable)
InAir ADSS Light Fiberglass (Multi-Tube Fiberglass Single Jacket Cable)
Metallic aerial self-supporting (MASS)